A non-programmable digital thermostat controls the DITRA-HEAT-E-HK heating cables, which are either 120 V or 240 V.
It features a built-in Class A ground fault circuit interrupter (GFCI) with an indicator light and a floor temperature sensor.
DITRA-HEAT-E-R is operated via a simple on/off switch.
Connect two heating cables to the thermostat up to the total heating load limit of 15 amps.
The DITRA-HEAT-E-RR power module may be used with the thermostat when the heating load exceeds 15 amps.
In large floor applications) to maintain a single point of control.
DITRA-HEAT-E-R must be installed in an electrical box. A single gang, deep electrical box, or a double gang electrical box with a single gang mud ring is recommended to provide room for the wiring
Heating cable leads must be wired in parallel according to applicable electrical and building codes
Multiple DITRA-HEAT-E-HK heating cables over 15 amps cannot be connected to a single DITRA-HEAT-E-R thermostat. Additional DITRA-HEAT-E-R thermostats must be used, or the DITRA-HEAT-E-R thermostat may be combined with the DITRA-HEAT-E-RR power modules.